14
41557-01 3/12/2002
®
Bare or Green
Green
Approved
Connectors
Power
Wires
In 
Ceiling
White
White
Black
Black/White
1
2
Connections:
Black
Wall Switch Wire For 
Separate Control of Light Fixture
Ceiling
Plate
Outlet Box
2 x 4 Brace
Green Ground
Wire from Hanger
Pipe (not present 
with flush mounting
option)
3 Wires 
From Fan
(Note: Wall switch 
must be acceptable 
as a general-use
switch.)
Connect Blk/Wht Wire from fan
to Wall Switch Wire for separate
control of light fixture, or
Connect Blk/Wht Wire from fan
to Ceiling Black Wire if there 
is no separate Wall Switch Wire
for the light fixture.
1
2
4. Connect the wires as shown in
Figure 5b. To connect the wires,
twist the bare metal leads to-
gether. Place a wire nut over the
intertwined length of wire and
twist clockwise until tight as
shown.
Figure 5b - Wiring Diagram
5. Separate the connected wires by
placing the green and white wires
on one side of the outlet box and
the black and the black/white
wires on the other side of the
outlet box.
6. Turn the connectors upward. Push
the wires gently into the outlet
box.
CAUTION
Be sure no bare wire or wire
strands are visible after mak-
ing connections.