Maintenance
14.13
Check and service bat-
teries
X
Lubricate terminals X
Routine Maintenance
Item Daily 75hr 250hr Yearly
Tighten all pressurized
water system fittings
X
Item Daily 25hr 75hr 250hr Yearly
Miscellaneous
Halon Fire
Extinguishers
X X X X X
Check battery electro-
lyte level
X X X X X
Check raw water strain-
ers (generator, AC unit)
X X X X X
Item Daily Month 6 mo. Yearly
Generator
Inspect Generator X
Check oil level X
Check coolant level X
Check battery charging
system
X
Check antifreeze X
Check belt tension X
Check generator air
outlets
X
Clean generator assem-
bly
X
Change crankcase oil
and filter
X
Drain sediment from
fuel filter
X
Clean crankcase
breather
X
Change fuel filter X
Clean cooling system X
Check for fuel, oil, cooling, and exhaust leaks with set running.
Visually check belts for evidence of slippage.
On new generators, change after 35 hours of operation.
Perform more often in extremely dusty conditions.