Stop switch
Dismantling
Remove the earth screw (A) and cable (B).
Press the switch's securing tabs (C) towards
each other and push out the switch.
Cleaning and Inspection
Clean the switch and check its resistance as
follows:
Connect an ohm meter as shown in the fig.
The resistance should be:
In the stop position less than 0.1 ohm.
In the run position more than 1000 ohm.
Assembly
Fit the earth screw (A) and cable (B).
Note! On some models the earth cable should
be connected to the earth screw.