EasyManua.ls Logo

Husqvarna Jonsered CS 2250 - Starter Assembly - Refitting; Ignition Module - Testing

Husqvarna Jonsered CS 2250
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English – 27
Repair instructions
WARNING!
Make sure the recoil spring does
not fl y out and cause injury. Wear
eye protection..
7.4 Replacing a worn recoil spring
1
Remove the bolt from the centre of the pulley and
lift off the pulley and spring cassette.
2
Replace the defective spring cassette with a new
one.
3
Fit the bolt through the centre of the pulley and
tighten to a torque of 2–3 Nm.
Tension the recoil spring, see “Tensioning the recoil
spring”.
7.5 Starter assembly – refi tting
1
Position the starter assembly on the crankcase and
tighten the bolts to a torque of 2.5–3.5 Nm.
7.6 Ignition module – testing
If there is a fault in the ignition system the ignition
module must be tested before the ignition system
is removed.
Test the ignition module as follows:
Connect a test spark plug 502 71 13-01 to the
ignition lead and clip the test spark plug onto
the cylinder.
Turn the engine over using the starter cord.
If the test spark plug produces a spark the
ignition module is OK. (see gure 7)
Fig 7