EasyManua.ls Logo

Husqvarna LC 551 iV - Troubleshooting Schedule

Husqvarna LC 551 iV
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4 Troubleshooting schedule
Problem Possible cause Step Troubleshooting
To do
The prod-
ucts stops
when it is
operated,
the warn-
ing indica-
tor flash-
es.
The warning indicator shows
the error code 17: Cooling
fan, battery box 1 abnormal
alarm.
1
Do a check of the cooling fan in battery box
1. Make sure that it operates when the cut-
ting motor is on.
Replace the cooling
fan assembly.
The warning indicator shows
the error code 18: Cooling
fan, battery box 2 abnormal
alarm
1
Do a check of the cooling fan in battery box
2. Make sure that it operates when the cut-
ting motor is on.
Replace the cooling
fan assembly.
The warning indicator shows
the error code19: Battery
packet in battery box 1 con-
nection active alarm.
1
Connection problems between the product
and the battery. Do a check of the yellow
wire between battery 1 and the primary
control panel.
Replace the wires
to the batteries or
the primary control
panel.
The warning indicator shows
the error code 20: Battery
packet in battery box 2 con-
nection active alarm
1
Connection problems between the product
and the battery. Do a check of the yellow
wire between battery 2 and the primary
control panel.
Replace the wires
to the batteries or
the primary control
panel.
36 - Troubleshooting 1292 - 001 -