REMOTE CONTROL KIT (Optional)
The control settings listed in the preceding tables are those that will provide proper case performance. If
these spot display refrigerators are to be multiplexed with different types of refrigerator models, we
suggest that each spot display refrigerator be equipped with a “REMOTE CONTROL KIT”.
The remote control kit will insure better control of refrigeration temperature and provide additional
defrost controls that maybe needed since most other refrigerators do not have similar defrost frequencies
and terminations (fail safeguards) with these spot display refrigerators.
The remote-control kit will be factory installed below the display area of the spot display refrigerator. A
liquid line solenoid valve will also be installed.
The liquid line solenoid valve will open when energized. During refrigeration, the valve is controlled by
the refrigeration thermostat (close-on-rise of temperature) providing better and more specific control of
refrigeration temperature. The defrost timer controls the valve for defrost; closing the valve for
initiation; opening the valve at termination.
The remote control kit timer must be synchronized with the timer of the unit.