P/N 0562873_M 4-3
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Q1, Q2, Q3 Merchandisers
CLEANING COILS
Condenser coils should be cleaned at least once
per month. Additional cleaning may be needed
depending on the operational environment. A
dirty condenser blocks normal airflow through
the coils. Airflow blockage increases energy
consumption and reduces the merchandiser’s
ability to maintain operating temperature.
To clean the coils, use a vacuum cleaner with
a wand attachment and a soft (non-metallic)
brush to remove dirt and debris. Do not bend
coil fins. Always wear gloves and protective
eye wear when cleaning near sharp coil fins
and dust particles.
CONDENSER COIL ACCESS
Remove the cover & close off frontal caster to access condenser coil.
COVER
CONTROL ACCESS
CLOSE OFF
FRONTAL CASTER