Beethoven, Beethoven H, Mozart, Ravel,Vivaldi & Hwam 30
Air inlet controls
Lighting
(Diagrams A1)
The regulation rod (1) is pushed farthest to the right and the sliding air wash damper in or under the door (2) is
opened completely.
Follow the general lighting instructions on pages 8 and 9.
Keep the fire box door slightly open until there is no condensation on the glass (approx. 5-10 minutes) then shut
the door.
The stove should never be left unattended when the fire box door is open.
When all the fire has established, the burn rate control rod (1) should be pushed to the middle position as should
the sliding air wash damper (2).
Important!
Do not open the ash pan door when lighting the stove and always keep it closed when the stove is in use,