6. Specifications
Model
PF30LC PF50L
C
PF90LC
Maximum water pressure to pressure reducing valve 12 bar
Power (kW)*
3.0
Voltage (V) 230V ~ 50 Hz
Current (A) 13A
Capacity (Litres) 30 50 90
Operating Pressure 3 bar
Maximum design pressure 6 bar
Expansion vessel charge pressure 3 bar
Expansion relief valve setting 6 bar
Pressure Reducing Valve setting 3 bar
Temperature and Pressure Relief 7 Bar 90 degrees°C
Minimum recommended pressure 0.8 bar
Immersion heater specification Hyco PFEL30 EN60335 x 1
Weight empty (kg) 9 13 24
Weight full (kg) 39 63 114
Heat up time (from 13°C to 60°C) in minutes 21 40 86
Reheat time (70% contents to 60°C) in minutes 16.5 28 57
Standing heat losses(kW/h) 0.93 1.16 1.26
Height (mm) 620 915 930
Width (mm) 380 380 540
Depth (mm) 295 295 385
Tank Material Stainless steel
Inlet / Outlet ½ ” BSP male
Powerflow_Layout 1 28/06/2015 10:09 Page 9
*Units also available with 1kW element. Add suffix of 1KW to product code e.g. PF30LC1KW