1
GA-170 Gas Detector
Operation and Maintenance Manual
GA-170 Rev. 7/6/12
The information contained in this manual was current at the time of printing. The most current versions of all
Hydro Instruments manuals can be found on our website: www.hydroinstruments.com

Questions and Answers

  • W
    William StevensAug 6, 2025
    What to do if the display is blank on Hydro Instruments Gas Detectors?
    • T
      Timothy MillsAug 7, 2025
      If your Hydro Instruments Gas Detectors display is blank, the possible causes are: * Loss of A/C power: Check the A/C power. * Damaged circuit board: Replace the circuit board. * Blown fuse: Replace the fuse.
  • B
    bryantkatherineAug 12, 2025
    Why is my Hydro Instruments GA-170 showing a high reading or not returning to zero?
    • S
      Stephen KimAug 13, 2025
      If your Hydro Instruments Gas Detectors show a high reading or the reading won’t return to zero, it might be caused by a damaged sensor. In this case, replace the sensor.
  • D
    David SmithAug 19, 2025
    What to do if Hydro Instruments GA-170 Gas Detectors have a negative reading & no response with Alarm Status: Error?
    • J
      Jeremy ValdezAug 19, 2025
      If your Hydro Instruments Gas Detectors show a negative reading and no response with Alarm Status: Error, the possible causes are: * Sensor disconnected: Check the sensor wiring. * Sensor damaged: Replace the sensor.
  • K
    Kevin MarksAug 25, 2025
    Why do Hydro Instruments GA-170 Gas Detectors read zero & no response with Alarm Status: Normal?
    • K
      Kaylee BarreraAug 25, 2025
      If your Hydro Instruments Gas Detectors show zero & no response with Alarm Status: Normal, the possible causes are: * Calibration cap not removed: Remove the calibration cap. * Wrong span calibration: Correct the span calibration.
  • J
    jasonroseAug 30, 2025
    How to fix slightly off zero reading in air for Hydro Instruments Gas Detectors?
    • M
      melissacurryAug 30, 2025
      If your Hydro Instruments Gas Detectors are slightly off zero in air, it might be caused by an inaccurate zero calibration. To resolve this, perform a zero calibration.

Summary

Installation and Operation Guide

Gas Detector Installation and Startup

Details initial power-up, sensor communication, gas density, and protection for installation.

Alarms and Signal Outputs

Explains alarm acknowledgment, 4-20mA output, and alarm relay functions.

GA-170 Operation Screens Overview

Describes the features of the standard operating screens and navigation.

Battery Backup Installation and Function

Guides on disconnecting A/C power and installing the battery for backup.

Parameter Configuration and Calibration

Accessing Setup Mode

Details how to access the password-protected setup section for configuration.

Configuring Sensor Channels

Explains selecting display units, enabling battery backup, and configuring each sensor channel.

Troubleshooting Gas Detector Issues

Pre-Installation Checks

Reviews sensor and monitor installation points to ensure proper setup.

Common Symptoms and Solutions

Lists common symptoms, their likely causes, and recommended troubleshooting steps.

Detailed Troubleshooting Explanations

Provides detailed explanations for calibration, sensor wiring, and other troubleshooting steps.

Hydro Instruments GA-170 Specifications

General IconGeneral
Sensor TypeElectrochemical
Operating Temperature-20°C to 50°C
Response Time<15 seconds
AlarmVisual and audible alarms
Dimensions30 mm
Weight120 g
Operating Humidity15-90% RH non-condensing