Once a day the pumps and blower turn on to prevent the spa water from becoming
stagnant in the plumbing lines of the therapy jets and blower lines when the spa used
very little and improves the skimmer action to remove debris and suspensions from the
water surface, once per day at the start first “filtration” cycle the blower purges all air
lines for 30 seconds and pumps purge all plumbing lines and agitate water for 5
minutes.
In a 24 hour circulation system the “filtration cycle” program operates only on limited
base. In economy mode, when actual water temperature of the spa is below the
set temperature the heater will turn on only during the “filtration cycle”. The default
setting of the filtration cycle is 2 hours, twice per day.
Heater
Your spa is equipped with an electrical heater. By setting your thermostat to the
desired temperature, your heater will automatically turn on and off as needed. The
temperature set point (set temperature) can be adjusted from 80°F to 104°F/26°C-
40°C). To raise the set temperature press the “Warm” button. To lower the set temper
ature, press the “Cool” button. The start up temperature is set at 100°F/37.5°C.
"Simplified freeze protection"
If a freeze condition is detected (temperature of heater enclosure is less than 44° F, the
pump(s) are automatically activated until the temperature of the heater enclosure
reaches 45° F. If this occurs contact your dealer.
2. Air Volume Control
Your spa is equipped with Air Volume Controls. Each jet system has its own air control. These con-
trols allow you to regulate the amount of air which is mixed with the water entering through the jets.
Counterclockwise rotation adds more air and clockwise rotation reduces air flow. To minimize heat
loss, these controls should be closed when the hot tub is not in use.
3. Waterfall control
Turn the waterfall valve clockwise to decrease or turn off waterfall output. It takes four full revolutions
to change the waterfall from full off to a full on flow rate.
4. Adjusting Jets
All jets in your new spa can be adjusted for high and low impact massage, providing an ultimate
massage. Each jet has its own water volume and directional or oscillating flow adjustment.
To adjust jets:
Turn outer dial counterclockwise to increase water volume. Turn outer dial clockwise to decrease
water volume or to shut jet off.
For adjustment of the directional jets move the nozzle of jet to any angle.
5. Aromatherapy
Simply remove the Aromatherapy injector cap, drop in the injector basket of your favorite scented
beads. When the Air blower is activated, the scent will be released into the spa vapor through the air
injectors. See your dealer for replacement of scented beads.
14
OPERATING INSTRUCTIONS - HS200