EasyManua.ls Logo

Hydrovane HR04E10-4035S000 - User Manual

Hydrovane HR04E10-4035S000
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HR04-HR07 Models
User Handbook
(Original Instructions)
CC1132751D 10/2018
GB
Question and Answer IconNeed help?

Do you have a question about the Hydrovane HR04E10-4035S000 and is the answer not in the manual?

Summary

Introduction and Product Overview

Warnings, Cautions and Notes

Identification of hazard symbols for electric shock, danger, and hot surfaces.

General Warnings and Safety Symbols

Explanation of various warning symbols for safe operation and potential hazards.

Product Information

Health and Safety Precautions

Essential safety instructions for competent persons operating and maintaining the compressor.

Technical Data HR04-HR07

Installation Procedures

Compressor Ventilation

Ensuring adequate airflow for cooling by proper positioning of intake and outlet.

Electrical Connections

Critical safety warnings for electrical connections performed by qualified electricians.

Electrical Installation

Precautions and steps for safe mains electrical connection and isolator use.

Compressor Rotation

Procedure to check and correct compressor rotation to prevent serious damage.

Operating Instructions

Checking Procedure Before Starting

Pre-start checks including oil level, leaks, valve position, and emergency stop.

Starting Automatic Operation

Procedure and warnings for starting the compressor in automatic operation mode.

Starting Continuous Operation

Instructions for starting the compressor in continuous operation mode.

Starting Regulated Speed;RS

Starting procedure for variable speed (RS) models to match system demand.

Emergency Stop

Procedure for using the emergency stop button and resetting the unit.

Adjustments and Settings

Pressure Adjustment

Warning and procedure for pressure adjustments by trained service engineers.

Pressure Control RS Compressors

Adjusting load/cut-in and unload/cut-out pressures for RS compressors.

Maintenance Procedures

Routine Service

Recommended routine service tasks based on running hours and conditions.

Service Instructions

Critical safety warnings before performing maintenance on the compressor.

Electrical Connections

Checks for overheating and tight connections on electrical components.

Controller Messages and Faults

Warning;Faults

Information on warning and fault messages, their meaning, and rectification.

Hydrovane HR04E10-4035S000 Specifications

General IconGeneral
ModelHR04E10-4035S000
CategoryAir Compressor
Power SourceElectric
Power4 kW
Pressure10 bar
Drive TypeDirect Drive
Noise Level68 dB(A)
Voltage400V
TypeRotary Vane
Motor Power4 kW
Maximum Pressure145 psi
Free Air Delivery (FAD)0.35 m³/min

Related product manuals