9.3 Removing and Cleaning the Steam Cylinder
Warning: Please follow the detailed instructions in these operat-
ing instructions! The unit is only to be serviced by qualified,
authorized personnel. Note the warnings and safety notes in the
operating instructions. Failure to observe warnings and safety
notes may result in injury, serious injury or death, and/or dam-
age to the unit. The steam cylinder may still be hot when you
begin maintenance work. Handle carefully!
Note: After a longer period of operation the steam cylinder could
shrink a little. This doesn‘t matter but could lead to tightness dis-
crepancies when only one half of the cylinder is being
exchanged. Therefore we recommend not to change only one
half of the cylinder but a complete cylinder.
Warning: Both the clamps that fix the steam cylinder halves and
the electrodes have sharp edges and angles that possibly could
lead to cut injuries.
on/off switch
in position II
after cylinder draining switch off unit
disconnect unit from
voltage supply
open unit