HHT-5000/6000/8000/10000/12000 USER MANUAL 26
Surge protection
DC Type Ⅱ,AC Type
Battery revers protection
Integrated
GENERAL DATA
Dimensions(W*H*D) mm
425*351*200
Weightkg
20
Noise emission(typical) dB(A)
<40
User Interface
LED/LCD
DC connection type
MC4
AC connection type
Plug-in Connector
Battery connection type
Sunclix
Communication
WiFi/4G(optional)
Cooling method
Natural Cooling
Operating ambient temperature
range
-25….+60
Allowable relative humidity
range
0%~100%
Max. operating altitude(m)
2000(>2000 derating)
Degree of protection(IEC 60529)
IP65
Climatic category IEC 60721-
3-4)
4K4H
Isolation method
No-isolated
Power loss in night mode
<13W
STANDARD
Safety
IEC62109-1/IEC62109-2/IEC61727
EMC
EN 61000-6-1 / EN 61000-6-2 / EN61000-6-3
Cetification
CEI 0 /EN50549
Inverter power quality response modes
Power quality response modes
Default operation per AS/NZS 4777.2:2015
Volt-watt response mode
Default: Enabled
Volt-var response mode
Default: Disabled

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypontech HHT-12000 Series and is the answer not in the manual?

Hypontech HHT-12000 Series Specifications

General IconGeneral
BrandHypontech
ModelHHT-12000 Series
CategoryInverter
LanguageEnglish

Related product manuals