HHT-5000/6000/8000/10000/12000 USER MANUAL 34
12. SYSTEM MAINTENANCE
For the inverter’s long-term performance, it is suggested to maintain your inverter
regularly:
Content
Maintenance Measures
Cycle
System
Cleaning
• Check if the heat sink is covered and dusted
Maintenance of DC Switch can be performed at
night. Turn the switch to ON and OFF positions
for 4~5 times.
Use a wet cloth to clean the display
Annually OR Half a year
System Status
Inspect the enclosure for damage/deformation
Listen for abnormal noises during operation
Check if the parameters are normal during
operation
Half a year
Commissioning
Check if the cables are loose
Check if the cable insulations are damaged,
especially the parts in contact with metal surfaces
Half a year after first
commissioning
Annually OR Half a year
Grounding
• Check if the cables are securely grounded
Half a year after first
commissioning
Annually OR Half a year
NOTICE
HEAT SINK MIGHT INDUCE INJURY
When the inverter is operating, the heat sink might exceed 60
Please disconnect all electrical cables and connections. Wait for the inverter to
cool down completely.
Use compressed air cleaning or a soft brush to clean the inverter heat sink.
ALL aggressive chemicals, cleaning solvents or strong detergents are FORBIDDED