4 mm² 59 m 44 m 27 m
6 mm² 89 m 67 m 40 m
Conduc
tor
cross-
section
Maximum cable length
HPS-3680/
HPS-
3680D
HPS-4000/
HPS-
4000D
HPS-5000/
HPS-
5000D
HPS-6000/
HPS-
6000D
HPS-6000/
HPS-
6000D
4 mm² 25 m 20m 16m 12m 10m
6 mm² 40 m 30m 24m 20m 16m
The required conductor cross-section depends on the inverter rating, ambient
temperature, routing method, cable type, cable losses, applicable installation
requirements of the country of installation, etc.
5.3.2 Grid connection
Procedure:
1. Switch off the miniature circuit-breaker and secure it against being inadvertently
switched back on.
2. Insert the conductor into the suitable ferrule acc. to DIN 46228-4 and crimp the
contact.