2 | www.hysecurity.com SMART DC BOARD INSTALLATION INSTRUCTIONS D0360 REV. I ©2018
SMART DC CONTROLLER WORKSHEET
Table 1. User Menu
User Menu Item*
Default
Setting
Display
Setting
CT _ Close Timer 0
HC _ Hold to Close 0
HO _ Hold to Open 0
AP _ AC Loss function 0
RO_ Radio Open/Close 0
BF _ Warn Before Operate 2
FA _ Forced Open Alert 0
DA _ Drift Close Alert 0
PE _ Photo Eye Alignment 0
CL_ Set Clock (24 hour) 0
LD_ LCD Contrast setting 5
US_ Clear count 0
CA_ Close Limit Adjustment 0
AL_ Flash on Close Limit 1
DS_ Diagnostic Log 0
PD_ Set password 0
NOTE: Available menu items are dependent on operator type
and programming congurations or options.
Table 2. Installer Menu
Installer Menu Item*
Default
Setting
Display
Setting
BY _ Build Year
1
0
OT _ Select Operator Type 0
MN _ Model Number 0
S1_ Sensor 1 Type
1
0
S2_ Sensor 2 Type
1
0
S3_ Sensor 3 Type
1
0
LL _ Learn Limits 0
UC _ Usage Class 0
SH _ Gate Handing 0
WT _ Gate Weight (lbs) 0
LN _ Gate Length (Feet) 0
OS _ Open Speed 5
CS _ Close Speed 5
FD _ Load Factory Defaults 0
DG _ Dual Gate 0
1
See "Setting the Build Year" and Table 3 on page 5
2
Setting dependent on BY. S1, S2, S3 appear if BY is set to 2 or
higher.
NOTE: Available menu items are dependent on operator type
and programming congurations or options.
Table 2. Installer Menu
Installer Menu Item*
Default
Setting
Display
Setting
SG _ Sequenced Gate 0
CH _ Charger Type 0
OC_Emergency Close 0
BT_ Battery type 0
FO _ Fire Dept. Open 0
DR_ Reversing Sensor 0
SE _ IES Sensitivity 2
SS _ Inherent sensor Stop 0
LC _ Leaf Delay Close 0.0 Secs
LO_ Leaf Delay Open 0.0 Secs
RT _ Maximum Run Timer 30 Secs
PO _ Partial Open distance 0
EC _ Eye Close Logic 0
EO _ Eye Open Logic 0
GR _ Gate Edge Logic 0
SR _ IES Sensor Logic 1
PC _ Photo Eye Contact NC
2
0
GC _ Gate Edge Output NC
2
0
DT _ Disable Free Exit 0
OR _ Outside Obstr Loop 1
IR _ Inside Obstr Loop 1
HD _ Center Loop Hold 1
DL _ Detector Logic 1
CR _ RLD Reverse Open 0
CB _ RLD Disables ELD 0
CP _ Counts PBO 0
EB _ ELD Back off - Detector 0
R1 _ Relay 1 Logic - disabled 0
R2 _ Relay 2 Logic - Close Limit 1
R3 -R10 Multiple Relay Logic 0
TL _ Gate Open alert 2
LT _ Loitering alert 3
BA_ Break Away (Arm only) 0
SA _ SDC Address 0
NE_ Network Address 0
ELD _ Exit Loop Set 0
ILD _ Inside Obstr. Loop Set 0
OLD _ Outside Obstr. Loop Set 0
CLD _ Center Loop Set 0
1
See "Setting the Build Year" and Table 3 on page 5
2
Setting dependent on BY. S1, S2, S3 appear if BY is set to 2 or
higher.
NOTE: Available menu items are dependent on operator type
and programming congurations or options.