P1.17 4th Function In Speed
This parameter allows the user to adjust the maxi-
mum 4th Function In speed. The setting range is
from 1 to 9. Setting this parameter to "9" will result
in maximum 4th function speed. Setting this pa-
rameter to "1" will result in minimum 4th function
speed.
P1.18 4th Function Out Speed
This parameter allows the user to adjust the maxi-
mum 4th Function Out speed. The setting range is
frm 1 to 9. Setting this parameter to "9" will result
in maximum 4th function speed. Setting this pa-
rameter to "1" will result in minimum 4th function
speed.
P1.40 Sideshift Speed Free
This parameter allows the user to adjust the maxi-
mum sideshift speed when the mast is raised above
freelift position. The setting range is from 1 to 9.
Setting this parameter to “9” will result in maxi-
mum sideshift speed. Setting this parameter to “1”
will result in minimum speed.
OPERATOR PASSWORDS
The operator passwords are stored in a directory
which can be accessed from this menu. The supervi-
sor can add, edit, or delete operator passwords and
clear the Operator Log from this menu. See Ta-
ble 6. Scroll through the Password menu using the
UP (#1) and DOWN (#3) buttons and press the
RIGHT (#2) button to enter the desired selection.
Press the LEFT (#4) button to return to the previ-
ous menu.
Password - In the password display, you are
allowed a five digit password utilizing the
numbers 1 through 5 (zero is not a valid
number). Values between 11111 and 55554
are valid.
Alphanumeric Name - In the password dis-
play, you are allowed characters to insert a
name. All characters and numbers are al-
lowed. Use the UP (#1) and DOWN (#3) but-
tons to scroll through the characters and
press the Enter (#5) button to enter the de-
sired selection.
Mode Limit - For each password, you can
set the maximum performance mode al-
lowed. The performance mode is set under
the "M" character of the password display.
The number correlates directly to the per-
formance modes 1 through 4, plus "A" = all.
User Type - For each password, you can set
the access level or "User Type" under the "U"
character. The "O" is selected for operator,
the "S" for supervisor and the "T" for the
technician (service).
NOTE: A total of 100 passwords can be setup. Mul-
tiple passwords can be setup for either service, op-
erator, or supervisor but all have to be unique for
each.
NOTE: Parameter in Display "Perform Enable" set
to:
0 = Off, Operator can choose to set performance
mode.
1 = On, Operator is limited to the set performance
mode only.
Table 6. Operator Password Menu
PASSWORD Press Button ADD PASSWORD
DELETE PASSWORD
EDIT PASSWORD
OPERATOR PASSWORD
Supervisor-Level Menu 2200 SRM 2023
10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hyster C219 and is the answer not in the manual?

Hyster C219 Specifications

General IconGeneral
BrandHyster
ModelC219
CategoryForklifts
LanguageEnglish

Related product manuals