10
Exiting the emergency alarm:
The emergency alarm initiator exits the Emergency
mode in any of the following ways:
Press the programmed Emergency Off key.
Turn off the radio.
After the preset Alarm Cycles and Voice Cycles
expire, the radio will exit the Emergency mode
automatically (for None and 5-Tone only).
The emergency alarm receiving party exits the
emergency alarm in any of the following ways:
None: When the alarm is received, the receiving party
can press any key to exit the emergency alert. When
the alarm initiator exits the Emergency mode or when
the Alarm Cycles expire, the receiving radio will exit
the emergency alert automatically.
5-Tone: When an alarm is received, the receiving
party can press any key to exit the emergency alert.
HDC1200: When an alarm is received, the receiving
party can exit the emergency alert by pressing the
TK key within 2s after pressing the Back key, or
switching the channel or powering off the radio.
Call Only (HDC1200)
Initiating an emergency alarm:
1. Press the programmed Emergency key to go to the
Revert Channel, and the LED glows red.
2. If the feature “Alarm with Call to Follow” is enabled,
you can speak into the microphone to make an
emergency call when the LED glows red.
3. When the LED ashes orange, your radio can receive
voice.
Exiting the emergency alarm:
To exit the Emergency mode, press the programmed
Emergency Off key or power off the radio.
The emergency receiving party cannot exit the
emergency alarm manually. When the initiator exits the
alarm, the receiving radio will exit automatically.
Note: Your dealer may set the number of alarm
cycles and alarm duration (None, 5-Tone),
number of polite retries and impolite retries
(HDC1200), number of voice cycles, duration of
each transmission and TX interval.
Operation Method for Digital Emergency
Alarm
Initiating an emergency alarm:
Press the programmed Emergency On key send the
emergency information, and the LED glows red.
Exiting the emergency alarm:
The emergency alarm initiator exits the Emergency mode
in any of the following ways:
Press the programmed Emergency Off key.
Turn off the radio.
Once the emergency cycles expire, the radio will exit
the Emergency mode automatically.
When an alarm is received, the receiving party can exit
the emergency alert by pressing the TK key within 2s
after pressing the Back key, or switching the channel or
powering off the radio.
Alarm with Call
Initiating an emergency alarm:
1. Press the programmed Emergency On key to send
the emergency information, and the LED glows red.
2. When the LED glows red, you can hold the PTT
key and speak into the microphone to make an
emergency call.
Note: If the Alarm with Call To Follow feature is
enabled by your dealer, you can speak into the
microphone without holding the PTT key. If the
preset Voice Cycles expire, you can hold the
PTT key to make the emergency call again.
3. When the LED flashes orange quickly, you can
receive. And when a call is received, the LED glows
green.
4. If the preset Voice Cycles expire, you can hold the
PTT key to make the emergency call again (the LED
glows red). Release the PTT key to receive (the LED
ashes orange quickly); when a call is received, the
LED glows green solidly.
Exiting the emergency alarm:
To exit the Emergency mode, press the programmed
Emergency Off key or power off the radio.
When an alarm is received, the receiving party can exit
the emergency alert by pressing the TK key within 2s
after pressing the Back key, or switching the channel or
powering off the radio.
Emergency Call
Initiating an emergency alarm:
1. Press the programmed Emergency key to go to the
Revert Channel.
2. If the feature “Alarm with Call to Follow” is enabled,
you can speak into the microphone to make an
emergency call when the LED glows red.
3. When the LED ashes orange, your radio can receive
call.
4. If the preset Voice Cycles expire, you can hold the
PTT key to make the emergency call again (the LED
glows red). After the emergency call is transmitted,
please release the PTT key to receive.
Exiting the emergency alarm:
To exit the Emergency mode, press the programmed
Emergency Off key or power off the radio.
The emergency receiving party cannot exit the
emergency alarm manually. When the initiator exits the
alarm, the receiving radio will exit automatically.
Note: Your dealer may set the number of polite
retries and impolite retries, number of voice
cycles, duration of each transmission and TX
interval.

Other manuals for Hytera PD706

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hytera PD706 and is the answer not in the manual?

Hytera PD706 Specifications

General IconGeneral
BrandHytera
ModelPD706
CategoryPortable Radio
LanguageEnglish

Related product manuals