This function allows a user to determine whether a previously tightened nut still meets specification. In a typical
application the user sets the Torque Check value to 10% lower than the specification value. The operator pulls the
trigger and monitors the nut to detect any movement. Should movement be detected there is a good chance the nut
has loosened and will require retightening.
When data/documentation is exported the profile type for Torque Check is “TCK” and the data file records a successful
torque with the value checked.
NOTE: Torque Check is available on the LITHIUM SERIES II Tool 2000, 3000 and 5000 capacity versions.
TORQUE CHECK
(CONT’D.)(CONT’D.)