MESSAGE DEFINITION IMPACT ACTION
EARLY TRIGGER RELEASE
RETRY OPERATION
Trigger released before operation
complete
None Repeat operation
LOW BATTERY RECHARGE OR
CHANGE NOW
Battery is depleted None Re-charge or switch battery
OPERATION STOPPED RETRY
Tool has exceeded maximum safe
torque during either an angle or
torqueing operation.
Potential damage to tool Reduce angle or torque target
SUCCESS! OK TO RELEASE
TRIGGER
Operation completed correctly None None
TIMEOUT TRY AGAIN
Trigger held longer than necessary
to complete operation
None
Release trigger and repeat
operation
TIMEOUT WAITING FOR
TRIGGER RELEASE
Trigger held longer than necessary
to complete operation
None
Release trigger and repeat
operation
TRIGGER RELEASE
User did not release trigger after
completion of operation
None
Release trigger and select the
exit option
UNCALIBRATED TOOL Tool not calibrated Inaccurate bolting Calibrate tool
CODE DEFINITION
OK OK/Success
ETR Early Trigger Release
MHS Motor Has Stalled
BTS Below Target Speed
LBV Low Battery Voltage
MOC Motor Over Current
OT Temperature Exceeded
ME General Motor Error
ERROR MESSAGES
JOB DATA “RESULT” CODES
APPENDIX

Other manuals for Hytorc LITHIUM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hytorc LITHIUM Series and is the answer not in the manual?

Hytorc LITHIUM Series Specifications

General IconGeneral
BrandHytorc
ModelLITHIUM Series
CategoryTools
LanguageEnglish

Related product manuals