LITHIUM SERIES® II ELECTRIC TORQUE TOOL USER INTERFACE GUIDE
The tool recognizes a 3-letter “Profile Type” designation associated with each major bolting function. There are currently
five defined bolting functions and Profile Types as described in the table below. Note that dierent bolting parameters are
required for dierent bolting functions.
PROFILE TYPE PTYPE
BOLTING FUNCTION PROFILE TYPE PTYPE PARAMETERS
TORQUE TAR Torque Angle, Release and Fastener
SNUG SRF Snug Torque, Angle, Release and Fastener
TURNANGLE RAR Angle, Release, Fastener and Speed
TORQUE CHECK TCK Torque, Release and Fastener
ROTATIONS ROT Release, Torque Limit, Fastener and Number of Rotations
A Comma Separated Values (CSV) file - "PROFILES.CSV" - should contain one profile on each line. The profile data
structure includes a profile identifier (PID), a profile type (PTYPE) and a set of tool parameters defined for the particular
bolting function. Parameters not needed are set to zero.
Each line should contain a set of comma-separated values arranged as follows:
PID1, PTYPE, Parameter 1, Parameter 2, Parameter 3, Parameter 4
PID2, PTYPE, Parameter 1, Parameter 2, Parameter 3, Parameter 4
…
PID30, PTYPE, Parameter 1, Parameter 2, Parameter 3, Parameter 4
Note that the CSV file format does not specify units. The file format assumes the values are created with the working
knowledge of the application units set in the tool which can be adjusted in the Settings menu.
PROFILES CSV FILES
(CONT’D.)