13
Leading Innovation in Torque and Tension Since 1968
The World’s Most Trusted Industrial Bolting Systems
IMPORTANT: The reading of full preset pressure after the cylinder is extended DOES NOT
INDICATE that this pressure (torque) is applied to the bolt. It only indicates that the cylinder is fully
extended and cannot turn the socket further until the tool automatically resets itself.
Releasing the remote control button will retract the cylinder. The tool will automatically reset itself and the operator
will hear an audible “click” indicating he can again push the remote control button and the socket will turn. Each
time the cylinder is extended and retracted, it is called a cycle. Successive cycles are made until the tool “stalls” at
the pre-set Torque/PSI with an accuracy of ±3%.
IMPORTANT: ALWAYS ATTEMPT ONE FINAL CYCLE TO INSURE THE “STALL” POINT HAS BEEN
REACHED.
Releasing “LOCKED-ON” tools.
Should the tool “LOCK-ON” after the nal cycle, slide the disngage button with the pump off or in retract position.
Turn the pump back on and while maintaining the pressure, cycle the STEALTH tool in the pump’s manual mode.
Once you are able to press down the button without resistance,
continue holding the button down and release the advance pres-
sure on the pump. Shut off the pump, and remove the tool from
the nut.
STEALTH RELEASE PROCEDURE
1. Push remote to full pressure for nal stroke
2. Disengage the reaction pawl by holding the
button the direction of arrow
3. Release the rocker sw itch
4. Shut pump off
5. Remove tool
3-8
Loosening Procedures
First, set the pump to 10,000 PSI. Change the drive
direction to the loosening mode, assurring the reaction
arm abuts squarely off a solid reaction point. Press and hold the
remote control button down. Pressure will decrease as the socket
begins to turn. As the cylinder extends fully, you will hear an audible
“click”. Release the remote control button, and the cylinder automati
cally retracts, at which time you again hear the audible “click”.
Repeat this process until the fastener can be removed by hand.
NOTE: IF THE BOLT DOES NOT LOOSEN WITH THE
ABOVE PROCEDURE. IT IS AN INDICATION THAT YOU
REQUIRE THE NEXT LARGER SIZE TOOL TO LOOSEN
THE BOLT.
Use the safety handle to set and remove tools
Reaction Pad