EasyManua.ls Logo

IBM 8852 - BladeCenter H Rack-mountable - Removing and Replacing a Power Module

IBM 8852 - BladeCenter H Rack-mountable
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing and replacing a power module
Your BladeCenter might be equipped with 2900W power modules that have a
removable fan pack (part number 39Y7408), or it might be equipped with 2980W
high-efficiency power modules with integrated fan pack (part number 39Y7415).
The 2900W and 2980W high-efficiency power modules are not interchangeable
within the same power domain of the chassis. A power module configuration is
supported only if the two power modules are matched within the same power
domain:
v Power modules 1 and 2 provide power for domain A (blade slots 1 to 7)
v Power modules 3 and 4 provide power for domain B (blade slots 8 to 14)
The following is an example of a supported configuration:
v Domain A: Power Module 1; 2900W, Power Module 2; 2900W
v Domain B: Power Module 3; 2980W, Power Module 4; 2980W
This is an example of a non-supported configuration:
v Domain A: Power Module 1; 2900W, Power Module 2; 2980W
v Domain B: Power Module 3; 2900W, Power Module 4; 2980W
Attention: Failed power modules should only be replaced with the same type of
power module.
Note: The 2980W high-efficiency power modules are identified by a label on the
power module handle. Remove the top or bottom bezel as needed to access the
power module handle. 2900W power modules do not have this label.
2980 W High
Efficiency label
2980 W label
Chapter 4. Removing and replacing BladeCenter components 35