Table 4. Events for the Enclosure component (continued)
Event Event Type Severity Message Description Cause User Action
power_no_power STATE_CHANGE WARNIN
G
Power supply {0}
has no power.
Power supply has
no input AC power.
The power supply
may be turned off
or disconnected
from the AC supply.
N/A N/A
power_supply_absent STATE_CHANGE WARNIN
G
Power supply {0} is
missing.
The power supply
is missing
N/A N/A
power_supply_failed STATE_CHANGE WARNIN
G
Power supply {0} is
failed.
The power supply
state is failed.
N/A N/A
power_supply_off STATE_CHANGE WARNIN
G
Power supply {0} is
off.
The power supply
is not providing
power.
N/A N/A
power_supply_ok STATE_CHANGE INFO Power supply {0} is
ok.
The power supply
state is ok.
N/A N/A
power_switched_off STATE_CHANGE WARNIN
G
Power supply {0} is
switched off.
The requested on
bit is off, indicating
that the power
supply has not
been manually
turned on or been
requested to turn
on by setting the
requested on bit.
N/A N/A
sideplane_failed STATE_CHANGE ERROR sideplane {0}
failed.
The sideplane state
is failed.
N/A N/A
sideplane_ok STATE_CHANGE INFO sideplane {0} is ok. The sideplane state
is ok.
N/A N/A
temp_bus_failed STATE_CHANGE WARNIN
G
Temperature
sensor {0} I2C bus
is failed.
The temperature
sensor I2C bus has
failed.
N/A N/A
temp_high_critical STATE_CHANGE WARNIN
G
Temperature
sensor {0}
measured a high
temperature value.
The temperature
has exceeded the
actual high critical
threshold value for
at least one sensor.
N/A N/A
temp_high_warn STATE_CHANGE WARNIN
G
Temperature
sensor {0}
measured a high
temperature value.
The temperature
has exceeded the
actual high warning
threshold value for
at least one sensor.
N/A N/A
temp_low_critical STATE_CHANGE WARNIN
G
Temperature
sensor {0}
measured a low
temperature value.
The temperature
has fallen below
the actual low
critical threshold
value for at least
one sensor.
N/A N/A
temp_low_warn STATE_CHANGE WARNIN
G
Temperature
sensor {0}
measured a low
temperature value.
The temperature
has fallen below
the actual low
warning threshold
value for at least
one sensor.
N/A N/A
temp_sensor_failed STATE_CHANGE WARNIN
G
Temperature
sensor {0} is failed.
The temperature
sensor state is
failed.
N/A N/A
temp_sensor_ok STATE_CHANGE INFO Temperature
sensor {0} is ok.
The temperature
sensor state is ok.
N/A N/A
voltage_bus_failed STATE_CHANGE WARNIN
G
Voltage sensor {0}
I2C bus is failed.
The voltage sensor
I2C bus has failed.
N/A N/A
voltage_high_critical STATE_CHANGE WARNIN
G
Voltage sensor {0}
measured a high
voltage value.
The voltage has
exceeded the
actual high critical
threshold value for
at least one sensor.
N/A N/A
Chapter 1. Events 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Elastic Storage System 3000 and is the answer not in the manual?

IBM Elastic Storage System 3000 Specifications

General IconGeneral
BrandIBM
ModelElastic Storage System 3000
CategoryStorage
LanguageEnglish

Related product manuals