Table 5. Events for the physical disk component (continued)
Event Event Type Severity Message Description Caus
e
User Action
ssd_endurance_warn STATE_CHANGE WARNING The
ssdEndurancePerc
entage of GNR pdisk
{0} is on a warning
value.
The
ssdEndurancePerc
entage value is
warning.
The
ssdE
ndur
ance
Perc
enta
ge
value
of the
pdisk
is
betw
een
95
and
100.
SSDs have a nite lifetime
based on the number of
drive writes per day. The
ssd-endurance-percentage
values actually reported
will be a number between 0
and 255. This value
indicates the percentage of
life that is used by the
drive. The value 0 indicates
that full life remains, and
100 indicates that the drive
is at or past its end of life.
The drive must be replaced
when the value exceeds
100",
"state":"DEGRADED" }.
Recovery group events
The following table lists the events that are created for the Recovery group component.
Table 6. Events for the Recovery group component
Event Event Type Severity Message Description Caus
e
User Action
gnr_rg_failed STATE_CHANGE ERROR GNR recoverygroup
{0} is not active.
The recovery group is
not active.
N/A N/A
gnr_rg_found INFO_ADD_ENTITY INFO GNR recovery group
{0} was found.
A GNR recovery group
listed in the IBM
Spectrum Scale
conguration was
detected.
N/A N/A
gnr_rg_ok STATE_CHANGE INFO GNR recoverygroup
{0} is ok.
The recovery group is
ok.
N/A N/A
gnr_rg_vanished INFO_DELETE_ENTITY INFO GNR recovery group
{0} has vanished.
A GNR recovery group
listed in the IBM
Spectrum Scale
conguration was not
detected.
A
GNR
recov
ery
group
,
listed
in the
IBM
Spect
rum
Scale
con
gurati
on as
moun
ted
befor
e, is
not
found
. This
could
be a
valid
situat
ion.
Run the
mmlsrecoverygroup
command to verify that all
expected GNR recovery
group exist.
Chapter 1. Events 11