Table 5. Common installation system reference codes (SRCs): (continued)
System reference code Description Recovery steps
1100xxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
509Axxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
509Dxxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
50A4xxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
50ADxxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
50B1xxx AC input and power supply
related errors
1. Verify that line cords are plugged in correctly in the
draw, power distribution unit (PDU) (if applicable),
battery backup unit (BBU) (if applicable), and input
source power receptacle.
2. Verify that the Power Supplies are fully seated and
latched into position.
Starts with 27xxx, 28xx,
57xxx and ends with
xxxx3120, xxxx3121
Fiber channel port failure errors These errors are often caused by ports that are not used.
Every port must have a cable or wrap plug installed.
Whenever a cable is not installed, ensure a wrap plug is
installed for each unused port. Wrap plugs are shipped
automatically when a fiber channel feature code is
ordered.
B1A38B24 Network configuration error An invalid network configuration was entered by the
user. Often, a duplicate IP address was entered.
Cabling the server to the SDMC
The Systems Director Management Console (SDMC) controls hosts, including the management of virtual
servers and the use of capacity on demand. Using service applications, the SDMC communicates with
hosts to detect, consolidate, and forward information to IBM service for analysis.
22 Power Systems: Installing the IBM Power 720 Express (8202-E4B) and IBM Power 740 Express (8205-E6B)