9. Complete the IP address, Subnet mask, and Default gateway fields by using the values you
recorded in the Accessing the ASMI using a Web browser procedure.
10. Click OK > Close > Close.
Correcting an IP address
If you attach an Ethernet cable to the service processor before the system reaches power off standby, the
IP address shown in the service processor network configuration table might not be valid.
If a cable is attached and not connected to anything, nothing happens. The address could potentially
change if an Ethernet cable that is attached to a network is connected to that port and the system is
turned on. If you are unable to access the ASMI using a network connection, you must perform one of
the following tasks:
v Attach an ASCII terminal to the service processor using a serial cable. For details, see “Cabling the
server with an ASCII terminal” on page 23.
v Move the reset toggle switches on the service processor from their current position to the opposite
position. To perform this task, you must remove and replace the service processor. For details, contact
your next level of support.
32 Power Systems: Installing the IBM Power 720 Express (8202-E4B) and IBM Power 740 Express (8205-E6B)

Other manuals for IBM Power 740 Express 8205-E6B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power 740 Express 8205-E6B and is the answer not in the manual?

IBM Power 740 Express 8205-E6B Specifications

General IconGeneral
BrandIBM
ModelPower 740 Express 8205-E6B
CategoryServer
LanguageEnglish

Related product manuals