As NTP is drift based, large time differences can prevent NTP from synchronizing,
or cause synchronization to take a long time. It can be helpful to synchronize time
manually once and to verify that the time is picked up correctly afterward. Use the
separate commands of service ntpd stop , ntpdate your IP, and service ntpd
start. The following example shows the sequence:
[root@domain.node ~]# service ntpd stop
Shutting down ntpd: [ OK ]
[root@domain.node ~]# ntpdate 9.19.0.220
14 Jan 12:06:46 ntpdate[25360]: adjust time server 9.19.0.220 offset 0.003277 sec
[root@domain.node ~]# service ntpd start
Starting ntpd: [ OK ]
[root@domain.node ~]#
After the time on all of the servers is synchronized, you can verify that the logs
apply to your troubleshooting situation.
172 Storwize V7000 Unified: Problem Determination Guide Version

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 2076-124 and is the answer not in the manual?

IBM Storwize V7000 2076-124 Specifications

General IconGeneral
Model2076-124
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive Bays24
Processor Cores8
Operating Temperature10°C to 35°C
Power SupplyDual, Hot-swappable
Drive InterfaceSAS
Host Interface8 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
Cache Memory8GB

Related product manuals