EasyManua.ls Logo

IBM System x3550 M3 - Physical and Environmental Specifications; Dimensions, Weight, and Environment; Electrical and Thermal Specifications

IBM System x3550 M3
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IBM System x3550 M3 28
See the IBM ServerProven® website for the latest information about the specific versions and service
levels supported and any other prerequisites:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical and electrical specifications
Dimensions:
Height: 43 mm (1.7 in)
Width: 440 mm (17.3 in)
Depth: 711 mm (28.0 in)
Weight:
Minimum configuration 12.7 kg (28 lb)
Maximum configuration 15.9 kg (35.1 lb)
Supported environment:
Air temperature:
Server on: 10 to 35° C (50.0 to 95.0° F); altitude: 0 to 914.4 m (3,000 ft).
Decrease system temperature by 0.75° C for every 1,000-foot increase in altitude.
Server off: 5 to 45° C (41.0 to 113° F);
Shipment: -40 to +60° C (-40 to 140° F);
Humidity:
Server on: 20 to 80% , maximum dew point 21° C, maximum rate of change 5° C/hr
Server off: 8 to 80%, maximum dew point 27° C
Electrical:
Models with 675 W power supply
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 7.8 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.78 kVA
Models with 460 W power supply
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 2.6 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.53 kVA
BTU heat output:
Minimum configuration: 307 Btu/hr (90 watts)
Maximum configuration: 2660 Btu/hr (780 watts)
Acoustical noise level emission level:
6.1 bels (idling)
6.1 bels (operating)