EasyManua.ls Logo

IBM System x3850 - Memory Problems

IBM System x3850
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by ā€œ(Trained service technician only),ā€ that step must be performed only by a
trained service technician.
Symptom Action
The mouse or pointing device
does not work.
v Make sure that the mouse or pointing-device cable is securely connected to the
server and that the keyboard and mouse cables are not reversed.
v Make sure that the mouse device drivers are installed correctly.
v Try using another mouse or pointing device.
If
the problem remains, call for service.
Memory problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by ā€œ(Trained service technician only),ā€ that step must be performed only by a
trained service technician.
Symptom Action
The amount of system memory
displayed is less than the
amount of installed physical
memory.
Make sure that:
v The DIMMs are seated correctly.
v You have installed the correct type and capacity of memory.
v You have installed the DIMMs in the correct slots, in the correct order.
v If you changed the memory, you updated the memory configuration in the
Configuration/Setup Utility program.
v All banks of memory are enabled. The server might have automatically disabled
a memory bank when it detected a problem, or a memory bank might have been
manually disabled.
Look
in the POST error log for error message 289:
v If the DIMM was disabled by a system-management interrupt (SMI), replace the
DIMM.
v If the DIMM was disabled by the user or by POST, run the Configuration/Setup
Utility program and enable the DIMM.
v If this error remains, replace the DIMM.
If
the problem remains, call for service.
Chapter 6. Solving problems 55

Table of Contents

Related product manuals