Tag name ID 31
Minimum temperature before
exchanger exceeded.
1. This could be due to pressure drop in the
CO
2
installation.
Check that there is sufficient CO
2
in the
tank.
Yes, the tank is empty. Fill the tank.
Reset and restart
the Pelletizer.
No, the tank is full. Go to point 2
2. This could be due to pressure drop in
the CO
2
installation.
Check that manual valves are in the correct
positions.
CO2 gas valves is closed.
CO2 liquid valves is open.
Yes, a valve is not in
the correct position.
Set the valve to the correct position.
Reset and restart
the Pelletizer.
No, all valves is in the
correct position.
? Contact IceTech
technical support.