The physical distance from the pelletizer to firm/solid parts of the building is not less than
the distance indicated on the drawing.
For EU: Electrical connections have been established (3 x 400 VAC + N + PE, AC 50 Hz,
unless otherwise agreed upon).
For USA. Electrical connections have been established (3 x 480 VAC + PE, AC 60 Hz, unless
otherwise agreed upon).
Grid/Supply System: Solidly Grounded Wye Source.
The max. power requirement of the pelletizer is 32 amp.
The Pelletizer needs either an air supply or a CO2 gas supply, for the pneumatic system on
the machine.
Air supply: Maximum 10 bars pressure. Minimum 8 bars pressure. Flow minimum 150 liters
per minute.
Air quality: According to ISO 8573-1 Class 3 for environment temperature below + 5°C.
CO2 gas supply: Maximum 10 bars pressure. Minimum 8 bars pressure. Flow minimum 150
liters per minute.
CO2 gas quality: According to ISO 8573-1 Class 3 for environment temperature below +
5°C.
See specifications on page 4.