Tag name ID
20+21+22+23+24+25+26+27
Extruder 1 or 2 minimum or
maximum temperature for
degassing exceeded.
Alarm codes no
A500+B500+A1400+B1400
1. There could be CO
2
particles in the
degassing sytem.
Remove the degassing boxes and filters.
Check the degassing filters for wear or
damage.
Yes, the degassing filter is worn,
blocked or damaged.
Replace the component which are
broken or worn out.
Reset and restart
the Pelletizer.
No, there is no problems. Go to point 2
2. There could be CO
2
particles in the
degassing sytem.
Check the temperature transmitter and its
wire connections.
Yes, the transmitter is damaged or
wire connctions are instable.
Replace transmitter or repair the
wire connections.
Reset and restart
the Pelletizer.
No, there is no problems ? Contact IceTech technical support.