When NiMH&NiCd batteries are deeply discharged or left unused for a long
time, they will produce a false -
△
V which stops charging early. You can
disable -
△
V testing to avoid this problem.
Range: 0 –
30min (0, default)
Battery upper temperature limit. The battery temperature can be monitored
with the attached temperature sensor. In order to protect the battery from
damage due to high temperatures the iCharger will stop charging or
discharging immediately if the temperature exceeds the cut-off setting.
Users can choose
℃
or
o
F as the temperature unit
Range: 20 –
80
℃
℃℃
℃
(68 –
176
o
F).
o
F = (9/5)×
℃
℃℃
℃
+32.
Charging time upper limit. The charging process will stop immediately if it
exceeds the set value.
Range: 1 –
999min
Capacity protection. The charging/discharging process will stop immediately
if the calculated charge input/drained exceeds the set value.
Range: 100 –
99900mAh
Input voltage protection lower limit. The charging/discharging process will
stop immediately if the input voltage falls below the set value.
Range: 10.00 –
15.00V (10.00V, default)
Charge/Discharge power limit. The maximum charge/discharge power of
iCharger can be adjusted in order to limit internal temperature and to
protect the input current from over-loading. When the limit is set to AUTO
the iCharger can adjust the output charging power according to the input
capability.
CHG: 50 –
200W (180W for 106B
)
))
)
and AUTO.
DCHG: 5 –
30W (20W for 106B
)
))
)
Key confirmation and alert tone. If the keyboard sound is ON there will be a
beep when you press any key. If the buzzer is ON the iCharger will
generate an alert tone for certain events.
Key Beep: OFF&ON: (ON, default)
Buzzer: OFF&ON: (ON, default)
Process completion tone. Controls the tones generated at end of charging
or discharging and the cyclic charging/discharging indication.
Options: Beep 5 times, Beep 3 minutes, Beep always (continuous until
user presses STOP), Beep OFF
(Beep always, default)
Back-light and cooling fan control. Adjust the LCD backlight brightness.
There are three cooling fan modes: ON, OFF, AUTO. In AUTO-Mode,
iCharger adjusts the fan automatically to control its internal temperature.
Cooling fan: OFF, ON & AUTO: (AUTO, default)
Temp. Cut
Temp. CutTemp. Cut
Temp. Cut-
--
-Off
OffOff
Off
ON 50
ON 50ON 50
ON 50℃
℃℃
℃