SET MODE
5
SET mode programming
SET mode is used to change the condition of 11 transceiver
functions: beep tone function, monitor switch action, back-
lighting function, LCD contrast selection, auto power save
function, self check function, battery voltage indicator, signal
strength indicator, squelch sensitivity function, VOX gain* and
VOX delay*.
*Available for on-board use only.
D SET mode operation
q Turn power OFF.
w While pushing [SQL
MONI], turn power ON to enter the
SET mode.
bp (Beep tone function setting) appears.
e Push [SQLMONI] or [SQLMONI] and [Y]/[Z] to select the
desired item, if necessary.
r Push [Y]/[Z] to select the desired condition of the item.
t Push [16] to exit the SET mode.
D SET MODE ITEMS The displays show the default settings, and the selected item is displayed in the dotted circle.
Beep tone
Monitor switch Backlighting
LCD contrast
: Push
: Push and
Starting item
Push and
Battery voltage
Auto power save
Self check
Squelch sensitivity
Signal strength
indicator
VOX delay*
VOX gain*
*Available for on-board use only