4 - 2
4-2 PLL ADJUSTMENTS
REFERENCE 
FREQUENCY
LPL-A LOCK 
VOLTAGE
VCO-A LOCK
VOLTAGE
1LO-A 
OUTPUT 
LEVEL
LPL-B LOCK 
VOLTAGE
VCO-B LOCK 
VOLTAGE
1LO-B
OUTPUT
LEVEL
3LO
OUTPUT
LEVEL
S3LO
OUTPUT
LEVEL
 
ADJUSTMENT
 ADJUSTMENT  ADJUSTMENT CONDITION   
MEASUREMENT
 VALUE  
POINT
    UNIT LOCATION    UNIT  ADJUST
1
2
1
1
2
3
4
1
1
1
2
3
4
1
1
1
• Display freq.  : Any
•  Turn L52 on the PLL unit to 4 rota-
tion downside for presetting.
• Receiving
• Display freq.  : 0.030000 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 7.999999 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 19.999999 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 44.999999 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 60.000000 MHz
• Mode  : USB
• Receiving
• Display freq. 
:
 0.030000 MHz, 7.999999 MHz
 8.000000 MHz, 19.999999 MHz
 20.000000 MHz, 44.999999 MHz
 45.000000 MHz, 60.000000 MHz
• Receiving
• Sub display freq.  : 0.030000 MHz
• Mode  : USB
• Receiving
• Sub display freq. 
: 7.999999 MHz
• Mode  : USB
• Receiving
• Sub display freq. 
: 19.999999 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 44.999999 MHz
• Mode  : USB
• Receiving
• Display freq. 
: 60.000000 MHz
• Mode  : USB
• Receiving
• Sub display freq. 
:
 0.030000 MHz, 7.999999 MHz
 8.000000 MHz, 19.999999 MHz
 20.000000 MHz, 44.999999 MHz
 45.000000 MHz, 60.000000 MHz
• Receiving
• Display freq. 
: Any
• Receiving
• Display freq. 
: Any
• Receiving
PLL
PLL
PLL
PLL
PLL
PLL
PLL
PLL
PLL
Connect a frequency 
counter to the check 
point P81.
Connect an RF volt-
meter to the check 
point P81.
Connect a digital 
multimeter or oscil-
loscope to the check 
point LPA.
Connect a digital 
multimeter or oscil-
loscope to the check 
point LVA.
Connect an RF volt-
meter to the check 
point P351.
Connect a digital 
multimeter or oscil-
loscope to the check 
point LPB.
Connect a digital 
multimeter or oscil-
loscope to the check 
point LVB.
Connect an RF volt-
meter to the check 
point P651.
Connect an RF volt-
meter to the check 
point P701.
Connect an RF volt-
meter to the check 
point P801.
64.000000 MHz
Maximum level
(0 dB or more)
2.0 V
4.3 V
4.3 V
4.3 V
4.3 V
–2 dBm or more
2.0 V
4.3 V
4.3 V
4.3 V
4.3 V
–2 dBm or more
–16 dBm or more
–10 dBm or more
PLL
PLL
PLL
PLL
PLL
L52
 (R33 
for critical 
adjustment)
L81, L82
C154
C278
C258
C228
C208
Verify
C454
C578
C558
C528
C508
Verify
Verify
Verify