4 - 13
4-6 METER ADJUSTMENTS
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY
OPERATION
ENTERING
ADJUSTMENT
MODE
1 • Enter the adjustment mode:
  q Turn power OFF.
 
w
 Terminate the [REMOTE] jack 
with a 3.5(d) mm mini-plug.
 
e
 While pushing [SSB] and [CW/
RTTY], turn power ON.
      ADJUST MODE
Push [F-1 (METER)], [F-2 (TX)] or [F-3 (RX)] to 
select each adjustment mode.
Once entering adjustment mode, use [F-1 
(
▼
)] to skip items, or [F-2 (EXIT)] to return the 
opening display.
CAUTION:
NEVER
 select adjustment items [F-2 (TX)] while transceiver is connected to an SSG. Because transceiver auto-
matically transmits when transmit item in the [F-2 (TX)] is selected.
METER
SCALE
1• Push [F-1 (METER)] to enter the 
meter scale adjustment.
   -- METER --
    SCALE S1
Set the analog meter to S1 position using the 
tuning dial. Then push [F-5 (SET)] to store the 
“S1” meter into memory, and go to the next step.
2
   -- METER --
    SCALE S3
Set the analog meter to S3 position using the 
tuning dial. Then push [F-5 (SET)] to store the 
“S3” meter into memory, and go to the next step.
3
   -- METER --
    SCALE S5
Set the analog meter to S5 position using the 
tuning dial. Then push [F-5 (SET)] to store the 
“S5” meter into memory, and go to the next step.
4
   -- METER --
    SCALE S7
Set the analog meter to S7 position using the 
tuning dial. Then push [F-5 (SET)] to store the 
“S7” meter into memory, and go to the next step.
5
   -- METER --
    SCALE S9
Set the analog meter to S9 position using the 
tuning dial. Then push [F-5 (SET)] to store the 
“S9” meter into memory, and go to the next step.
6
   -- METER --
   POWER S+20
Set the analog meter to S9+20 position using 
the tuning dial. Then push [F-5 (SET)] to store 
the “S9+20” meter into memory, and go to the 
next step.
7
   -- METER --
   POWER S9+40
Set the analog meter to S9+40 position using 
the tuning dial. Then push [F-5 (SET)] to store 
the “S9+40” meter into memory, and go to the 
next step.
8
   -- METER --
   SCALE S9+60
Set the analog meter to S9+60 position using 
the tuning dial. Then push [F-5 (SET)] to store 
the “S9+60” meter into memory, and retuns to 
the opening display.
TX METER
( HF POWER
METER)
1
•  Push [F-2 (METER)] to enter the TX 
meter scale adjustment.
•  Connect an RF power to [ANT1] 
connector.
•  Connect a 100 
Ω
 dummy load to 
[ANT2] connector.
•  Connect audio generator to [MIC] 
connector  and set as:
         FREQUENCY   : 1.5 kHz
         LEVEL              : 10mVrms
   -- TX --
   POWER 0%
Push [F-5 (SET)] to store the “POWER 0%” 
meter into memory, and go to the next step.
2
   -- TX --
   POWER HF Tuner
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the 
“POWER HF Tuner” meter into memory, and 
go to the next step.
3
   -- TX --
   POWER HF 10%
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the 
“POWER HF 10%” meter into memory, and go 
to the next step.
4
   -- TX --
   POWER HF 25%
Set the output power to 25 W using the tun-
ing dial. Then push [F-5 (SET)] to store the 
“POWER HF 25%” meter into memory, and go 
to the next step.
5
   -- TX --
   POWER HF 50%
Set the output power to 50 W using the tun-
ing dial. Then push [F-5 (SET)] to store the 
“POWER HF 50%” meter into memory, and go 
to the next step.
6
   -- TX --
   POWER HF 100%
Set the output power to 104 W using the tun-
ing dial. Then push [F-5 (SET)] to store the 
“POWER HF 100%” meter into memory, and 
go to the next step.