REMOTE CONTROL
Remote control (CI-V) information
D Command formats
Scope waveform data
Command: 27 00
Outputs the waveform data to the controller (PC)�
X XX X0 0 X XX X
1 2 3 4 5
X X X X
......
X X
6 7
......
X X
1: 00 (Fixed)
2: Order of division data (Current): 01~11
3: Division number (Maximum): 01(LAN), 11(USB)
L When data is sent to the controller (PC) using the
[LAN] port, all data is sent together� However, when
the data is sent through the [USB] port, the data is
divided by 11 and sent in sequential order
L The 1st data sends only the wave information (1
~ 6) without the waveform data (7)� The 2nd or
later data sends “00” (1), the order of division data
(Current) (2), the division number (Maximum) (3),
and the waveform data (7)�
4: Spectrum scope mode data:
00 = Center mode scope
01 = Fixed mode scope
02 = SCROLL-C mode scope
03 = SCROLL-F mode scope
5: Waveform information:
The waveform information differs, depending on
the Spectrum scope mode�
In the Center mode:
Center frequency and span are sent�
See page 16 for Operating frequency data,
and the Scope span settings (2 ~ 6)�
L When the 5600 MHz or lower band is selected, the
Center frequency is 10 digits (5 bytes)�
When the 10 GHz band is selected, the Center
frequency is 12 digits (6 bytes) from 100 GHz to
1 Hz�
In the Fixed, SCROLL-C, and SCROLL-F modes:
Lower edge and higher edge frequencies are
sent�
See the Scope Fixed edge frequency settings 3
~ on page 29�
L When the Higher Edge or Lower Edge frequency is
in the 10 GHz band, the each Edge frequency is 12
digits (6 bytes) from 100 GHz to 1 Hz�
When the Lower Edge frequency is negative, the
100 GHz digit is set to “F,” and the other than 100
GHz digit are set to absolute value of the frequency
Scope span settings
(in the Center mode and SCROLL-C mode Scope)
Command: 27 15
0 0 0 0 X X X X X X 0 0
1
1 kHz digit: 0, 2, 5
100 Hz digit: 0, 5
100 kHz digit: 0, 1, 2, 5
10 kHz digit: 0, 1, 2, 5
10 Hz digit: 0 (Fixed)
1 Hz digit: 0 (Fixed)
10 MHz digit: 0, 1, 2
1 MHz digit: 0, 1, 2, 5
1 GHz digit: 0 (Fixed)
100 MHz digit: 0 (Fixed)
2 3 4 5 6
0 (Fixed)
0 (Fixed)
Span (kHz)
2500 2�5
5000 5
10000 10
25000 25
50000 50
100000 100
250000 250
500000 500
1000000 1000
2500000 2500
5000000 5000
10000000 10000
25000000 25000
Scope Reference level settings
Command: 27 19
0 0 X X X 0 0 X
00= + (plus)
01= – (minus)
10 dB digit: 0, 1, 2
1 dB digit: 0 ~ 9
0.1 dB digit: 0, 5
0.01 dB digit: 0
(Fixed)
0 (Fixed)
0 (Fixed)
Adjustable range: –20�0 dB ~ +20�0 dB
in 0�5 dB steps�
6: Out of range information:
00 = In range
01 = Out of range
L If the scope data is out of range, the waveform data
(7) is omitted�
7: Waveform data:
The transceiver outputs the drawn waveform data�
The data range or data length of the waveform
data is judged by the controller (PC)� (The data
range is basically the same as the display size of
the scope on the controller (PC)�)
Data range: 00 ~ A0 (0 ~ 160)
Data length: 475