Loading...
New2001
55
7
DSC OPERATION
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D Receiving an Individual Call
When an Individual Call is received:
The alarm sounds for 2 minutes.
“RCVD INDIVIDUAL CALL is displayed. The backlight may
blink for 2 minutes, depending on the received Category.
Push [ALARM OFF] to stop the alarm and the blinking q
backlight.
•Evenifyoudonotpush[ALARMOFF],thealarmstopsafter2
minutes, and then the screen in step w is displayed.
Push a softkey to select your desired action. w
[IGN]
Push to ignore the Call and return to the normal operating
mode.
•ThetransceiverexitstheDSCmode.
•“ continues to blink and the Call is stored in the Received
Call Log.
[INFO]
➥Push to display the Received call information. (p. 61)
[ACK]
Push to display the “INDIVIDUAL ACK” screen to reply
to the Call. Select one of three options, depending on
your situation. See page 32 for details of the Individual
Acknowledgement procedures.
When “INDIVIDUAL ACK” is set to “Auto TX (Unable),” the
transceiver automatically replies to the Call. In that case,
both the TX and RX calls are stored in the Transmitted and
Received Call Logs.