4-2
IF
CIRCUITS
4-2-1
TUNER
UNIT
(PLL
UNIT)
The
TUNER
UNIT
(EP2)
contains
an
RF
amplifier
controlled
by
the
ТАСС
signal,
mixer
and
4
VCOs.
Тһе
RF
signals
are
applied
to
P2
on
the
TUNER
UNIT
(EP2)
to
be
con-
verted
to
а
46
MHz
IF
signal.
Тһе
TUNER
UNIT
(EP2)
outputs
the
signal
from
pin
8.
IC2
on
the
LOGIC
UNIT
supplies
2-bit
data
to
IC11
(pin
3,
4).
IC11
is
ап
expander
for
switching
the
operating
band
of
TUNER
UNIT
(EP2).
The
following
table
(Fig
2)
shows
the
relations
between
2-bit
data
and
the
band
signal.
H:
High
level
No
indication:
Lovv
level
4-2-2
AMIFM
IF
AND
2ND
MIXER
CIRCUITS
(MAIN
UNIT)
The
46
MHz
IF
signal
passes
through
a
switching
diode
(D1)
with
AM
5
and
FM
5
signals
when
AM
or
FM
mode
is
selected.
The
signal
is
applied
to
an
IF
amplifier
and
then
applied
to
a
crystal
filter
(ЕП)
to
improve
the
selectivity.
The
filtered
signal
is
applied
to
a
2nd
mixer
(Q2)
and
then
mixed
with
the
35.3
MHz
2nd
LO
signal
to
produce
a
10.7
MHz
2nd
IF
signal.
A
35.3
MHz
2nd
LO
signal
is
generated
by
a
2nd
local
oscillator
circuit
consisting
of
D8,
X3,
Q5,
and
other
components.
The
2nd
LO
oscillator
circuit
produces
a
frequency
step
less
than
the
PLL
reference
frequency.
The
LOGIC
UNIT
supplies
D/A
converted
signals
to
IC10
(pin
3)
which
correspond
to
each
tuning
step.
The
signals
are
amplified
at
IC10
and
then
applied
to
a
varactor
diode
(D8)
which
shifts
the
oscillation
frequency.
АМІЕМ
IF
AND
2ND
MIXER
CIRCUITS
46.0
MHz
10.7
MHz
Q1
IF
|
PLL
IC
signal
(IC1,
pin
16)
AM,
FM
35.3
MHz
signal
DIA
signal
from
LOGIC
UNIT
Fig.
3
4—2
4-2-3
2ND
IF
AND
FM
DEMODULATOR
CIRCUITS
(MAIN
UNIT)
The
10.7
MHz
2nd
IF
signal
is
applied
to
ҒІ2.
Fl2
is
а
MCF
(Monolithic
Crystal
Filter)
which
suppresses
out-of-
band
signals.
The
2nd
IF
signal
is
applied
to
a
3rd
mixer
section
of
IC1
and
is
mixed
vvith
a
3rd
LO
signal
to
be
converted
to
a
455
kHz
3rd
IF
signal.
IC1
is
designed
for
use
in
FM
dual
conversion
com-
munications
equipment.
IC1
contains
the
3rd
mixer,
local
oscillator
circuit,
limiter
amplifier,
quadrature
detector
circuit,
and
active
filter
circuit.
The
local
oscillator
section
and
X1
generate
10.245
MHz
for
a
3rd
LO
signal.
The
3rd
IF
signal
from
the
3rd
mixer
(IC1,
pin
3)
passes
through
a
ceramic
filter
(F13)
where
unwanted
signals
are
suppressed.
It
is
then
amplified
at
the
limiter
amplifier
section
(IC1,
pin
5)
and
applied
to
the
quadrature
detector
section
(IC1,
pin
8
and
ceramic
discriminator
X2)
to
demodulate
the
3rd
IF
signal
into
an
AF
signal.
The
AF
signal
is
output
from
IC1
(pin
9).
4-2-4
AM
DEMODULATOR
CIRCUIT
(MAIN
UNIT)
A
portion
of
the
455
kHz
3rd
IF
signal
is
applied
to
an
IF
amplifier
(Q4)
after
passing
through
the
ceramic
filter
(FI3)
when
AM
mode
is
selected
by
switching
diodes
(D5,
D7).
When
the
switching
diodes
are
turned
ON,
AM
5
signal
line
obtains
5
V.
The
amplified
signal
passes
through
a
ceramic
filter
(Fl4)
to
improve
selectivity.
The
filtered
signal
is
re-amplified
at
an
IF
amplifier
(Q7)
and
then
rectified
by
the
AM
detector
circuit
(D10,
D11).
The
detected
signal
is
demodulated
into
an
AM
signal.

Other manuals for Icom IC-R100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-R100 and is the answer not in the manual?

Icom IC-R100 Specifications

General IconGeneral
BrandIcom
ModelIC-R100
CategoryReceiver
LanguageEnglish

Related product manuals