5-3
ADJUSTMENT ITEM
ADJUSTMENT
CONDITIONS
OPERATION VALUE
144 MHz BAND
TRANSMIT OUTPUT POWER
(HIGH POWER)
(Band Low)
[PHL]
1• Connect an RF power
meter to the antenna
connector.
• Transmitting
Rotate Band B [DIAL] to ad-
just the transmit output power,
and then touch [ENT] during
transmit.
50 W
(Band High)
[PHH]
2
(MID POWER) (Band Low)
[PML]
3 15 W
(Except
[TPE])
22 W
([TPE])
(Band High)
[PMH]
4
(LOW POWER) (Band Low)
[PLL]
55 W
(Band High)
[PLH]
6
430 MHz BAND
TRANSMIT OUTPUT POWER
(HIGH POWER)
(Band Low)
[PHL]
1• Connect an RF power
meter to the antenna
connector.
• Transmitting
Rotate Band B [DIAL] to ad-
just the transmit output power,
and then touch [ENT] during
transmit.
50 W
(Band High)
[PHH]
2
(MID POWER) (Band Low)
[PML]
3 15 W
(Except
[TPE])
22 W
([TPE])
(Band High)
[PMH]
4
(LOW POWER) (Band Low)
[PLL]
55 W
(Band High)
[PLH]
6
5-3 TRANSMIT ADJUSTMENTS
M TRANSMIT OUTPUT POWER ADJUSTMENTS
1) Select the adjustment item by rotating Band A [DIAL].
2) Set or modify the adjustment value as specifi ed, by rotating Band B [DIAL].
3) Touch [ENT] to store the value.