36 440 01 4300 00
Specifications subject to change without notice.
Table 13 Approved Combustion-Air and Vent Pipe, Fitting and Cement Materials (U.S.A. Installation)
ASTM
SPECIFICATION
(MARKED ON
MATERIAL)
MATERIAL PIPE FITTINGS
SOLVENT CEMENT AND
PRIMERS
DESCRIPTION
D1527
ABS Pipe Schedule40
D1785
PVC Pipe Schedule40
D2235
For ABS Solvent Cement For ABS
D2241
PVC Pipe SDR21 & SDR26
D2466
PVC Fittings Schedule40
D2468
ABS Fittings Schedule40
D2564
For PVC Solvent Cement For PVC
D2661
ABS Pipe Fittings DWV at Schedule40 IPS sizes
D2665
PVC Pipe Fittings DWV
F438
CPVC Fittings Schedule40
F441
CPVC Pipe Schedule40
F442
CPVC Pipe SDR
F493
For CPVC Solvent Cement For CPVC
F628
ABS Pipe
Cellular Core DWV at Schedule40 IPS
sizes
F656
For PVC Primer For PVC
F891
PVC Pipe Cellular Core Schedule40 & DWV
Figure 41
Vent Coupling and Adapter with
Gaskets
Vent Coupling and Adapter
Attach gaskets to vent pipe and combustion air adapters.
A11314
Figure 42 Vent Pipe Flush with Adaptor
VENT PIPE ADAPTER WITH GASKET
INSTALLED ON FURNACE VENT
PIPE IS CUT FLUSH WITH TOP OF
ADAPTER.
A11339A
Figure 43 Vent Pipe Flush Showing Coupling
ALIGN NOTCHES IN VENT PIPE
COUPLING OVER STANDOFF
ON ADAPTER. TORQUE LOWER
CL AMP 15 LBIN. WHEN REMAINING
VENT PIPE IS INSTALLED, TORQUE
UPPER CL AMP TO 15 LBIN.
A11339B