Installation Instructions
PHX3 Series
2 to 5 TON
PACKAGE HEAT PUMPS
TABLEOF CONTENTS
UNITDIMENSIONS ...................................... 2 - 3
SAFEINSTALLATIONREQUIREMENTS ......................... 4
LOCATINGTHE UNIT ....................................... 4
CLEARANCES ............................................ 4
INSTALLATION............................................ 5
GROUNDLEVELINSTALLATION .............................. 5
RooftopINSTALLATION..................................... 5
HOISTING................................................ 5
DOWNFLOWCONVERSION.................................. 5
CONDENSATEDRAIN....................................... 5
ELECTRICALWIRING................................... 6
DUCTWORK.......................................... 7
FILTERS ............................................. 7
AIRFLOWADJUSTMENT ................................ 8
START-UPPROCEDURES ............................... 9
SEQUENCEOF OPERATION.............................. 9
MAINTENANCE ...................................... 10
RIGGING ........................................... 12
WIRINGDIAGRAMS ................................... 13
_ CLIS_IEDUS
518 O1 1301 OO 1-4-O6
Printed in U.S.A.
CODE: PHX3
Question and Answer IconNeed help?

Do you have a question about the ICP PHX348000K00A1 and is the answer not in the manual?

ICP PHX348000K00A1 Specifications

General IconGeneral
BrandICP
ModelPHX348000K00A1
CategoryHeat Pump
LanguageEnglish

Summary

Safe Installation Requirements

Safety Considerations

Lists critical safety points for installation and maintenance.

Introduction

Provides a brief overview of the PHX3 unit and its design.

Locating the Unit

Access Panels

Refers to Figure 1 for unit access panel locations.

Clearances

Details minimum required clearances around the unit for operation and service.

Installation

Ground Level Installation

Details platform requirements for ground installations.

Rooftop Installation

Details platform requirements for rooftop installations.

Hoisting

Instructions for safely lifting and moving the unit.

Downflow Conversion

Steps to convert the unit for downflow air discharge.

Electrical Wiring

Disconnect Switch

Requirements for the field-supplied disconnect switch.

Ground Connections

Instructions for making the unit's ground connection.

Thermostat / Low Voltage Wiring

Guidance on thermostat and low voltage wiring.

Ductwork

Ductwork Sizing, Insulation, and Connections

Covers sizing, insulation, and connection requirements for ductwork.

Filters

Filter Sizes

Table listing recommended filter sizes for PHX3 units.

Airflow Adjustment

Circulating Air Blower Speeds

Table detailing blower speeds and air delivery at various static pressures.

Airflow Adjustment (cont.)

Instructions for verifying and setting blower motor speeds for heating and cooling.

Start-Up Procedures

Check Before Starting

Pre-start checks including filters and access panels.

Sequence of Operation

Cooling, Heating, and Defrost Operation

Describes sequences for cooling, heating modes, and defrost cycle.

Scroll Recycle Delay Timer

Explains the compressor recycle delay timer function.

Maintenance

Monthly Maintenance and Inspection Checks

Routine monthly checks for air filters and condenser coil.

Annual Maintenance and Inspection

Annual inspection tasks including fan motor and blower motor checks.

Rigging Instructions

Rigging Instructions

Detailed instructions and warnings for safe rigging and lifting.

Wiring Diagrams

2 to 5 Ton Wiring Diagram

Schematic diagram illustrating electrical connections for the unit.