Installation Instructions
PHX3 Series
2 to 5 TON
PACKAGE HEAT PUMPS
TABLEOF CONTENTS
UNITDIMENSIONS ...................................... 2 - 3
SAFEINSTALLATIONREQUIREMENTS ......................... 4
LOCATINGTHE UNIT ....................................... 4
CLEARANCES ............................................ 4
INSTALLATION............................................ 5
GROUNDLEVELINSTALLATION .............................. 5
RooftopINSTALLATION..................................... 5
HOISTING................................................ 5
DOWNFLOWCONVERSION.................................. 5
CONDENSATEDRAIN....................................... 5
ELECTRICALWIRING................................... 6
DUCTWORK.......................................... 7
FILTERS ............................................. 7
AIRFLOWADJUSTMENT ................................ 8
START-UPPROCEDURES ............................... 9
SEQUENCEOF OPERATION.............................. 9
MAINTENANCE ...................................... 10
RIGGING ........................................... 12
WIRINGDIAGRAMS ................................... 13
_ CLIS_IEDUS
518 O1 1301 OO 1-4-O6
Printed in U.S.A.
CODE: PHX3
Question and Answer IconNeed help?

Do you have a question about the ICP PHX330000K00A1 and is the answer not in the manual?

ICP PHX330000K00A1 Specifications

General IconGeneral
BrandICP
ModelPHX330000K00A1
CategoryHeat Pump
LanguageEnglish

Summary

Unit Dimensions

B Chassis Unit Dimensions

Details dimensions for the "B" Chassis heat pump units, including specific measurements for various components.

Roof Curb Dimensions for B Chassis

Provides dimensions for roof curbs designed for "B" Chassis units, specifying measurements for different configurations.

C Chassis Unit Dimensions

Details dimensions for the "C" Chassis heat pump units, including specific measurements for various components.

Roof Curb Dimensions for C Chassis

Provides dimensions for roof curbs designed for "C" Chassis units, specifying measurements for different configurations.

Safe Installation Requirements

Safety Warnings and Hazards

Highlights critical safety warnings, including electrical shock and fire hazards, emphasizing qualified personnel.

Safety Information Symbols

Explains the safety-alert symbol and signal words (DANGER, WARNING, CAUTION, NOTE) used in the manual.

Safety Considerations

Provides essential safety guidelines for unit installation, including positioning, static pressure, and filter checks.

Unit Introduction

Brief overview of the PHX3 unit as a self-contained electric heat pump designed for outdoor installation.

Locating the Unit

Guidance on selecting an appropriate location for the unit, considering sound and clearance requirements.

Clearances

Specifies minimum clearances required around the unit for safe operation and adequate air circulation.

Installation

Installation Notice

Important notice regarding unit leveling requirements for proper operation and drainage.

Ground Level Installation

Requirements for installing the unit on a ground-level platform, ensuring stability and drainage.

Rooftop Installation

Guidelines for rooftop installation, including structural support and platform requirements.

Hoisting

Instructions for safely hoisting the unit, emphasizing the use of spreader bars and secure rigging.

Downflow Conversion

Steps for converting the unit for downflow air discharge configuration.

Condensate Drain

Details on the condensate drain connection, including size and location.

Electrical Wiring

Reduced Equipment Life Hazard

Cautionary note regarding improper electrical connections potentially reducing equipment lifespan.

Disconnect Switch

Requirement for a field-supplied, waterproof disconnect switch for the unit's electrical service.

Ground Connections

Instructions for ensuring a permanent, uninterrupted electrical ground connection for safety.

Line Voltage Wiring

Guidance on making line voltage connections within the unit's control box, referencing wiring diagrams.

Thermostat / Low Voltage Wiring

Instructions for connecting the thermostat and low voltage wiring, emphasizing correct location and wiring.

Ductwork

Ductwork Sizing

Recommendations for ductwork velocity limits to ensure proper airflow and system efficiency.

Ductwork Insulation

Requirements for insulating outdoor ductwork with fiberglass wrap and a weatherproof vapor barrier.

Ductwork Connections

Guidelines for connecting supply and return plenums to the unit, ensuring proper sealing.

Filters

Filter Requirements and Sizes

Details the necessity of using filters and lists recommended sizes based on face velocities for optimal performance.

Airflow Adjustment

Blower Speed Selection

Information on blower speed taps and corresponding wiring for heating and cooling stages.

Speed Configuration Procedure

Procedure for setting blower motor speeds when the same speed is required for heating and low-stage cooling.

Start-Up Procedures

Check Before Starting

Pre-start checks including blower speed, air filters, and access panels before powering the unit.

Cooling Operation

Description of the cooling cycle operation, including staged cooling and fan control.

Heating Operation

Description of the heating cycle operation, including staged heating and auxiliary heat control.

Scroll Recycle Delay Timer

Explanation of the compressor recycle delay timer function to prevent reverse rotation.

Continuous Fan Operation

Details on continuous indoor fan operation and its effect on airflow settings.

Defrost Mode

Explanation of the defrost mode, including delay settings, sequence, and termination.

Sequence of Operation

Defrost Mode Operation

Detailed sequence of operation during defrost mode, including fan, reversing valve, and heat control.

Maintenance

Monthly Maintenance Checks

Routine monthly checks including air filters, condenser coil, and condensate drain for optimal performance.

Cooling Season Checks

Specific monthly checks recommended during the cooling season, focusing on condenser coil and drain.

Annual Maintenance and Inspection

Comprehensive annual inspection tasks, including fan motors, blower access, and motor replacement.

Rigging Instructions

Rigging Safety Precautions

Critical safety warnings for rigging, emphasizing panel placement, spreader bars, and secure shackles.

Rigging Dimensions and Weight

Table detailing maximum length, width, height, and weight for small and large cabinet rigging.

Wiring Diagrams

2 to 5 Ton Wiring Diagram

Schematic diagram illustrating electrical connections for 2 to 5 ton units, including component layout.