24
© 2014 ICS, Blount International Inc. Specications are subject to change
without notice. REV061914 F/N 545067
COLD ENGINE STARTING PROCEDURE
1. Pull the choke lever out, which also sets the throttle lock.
2. Depress primer bulb approximately 5-10 times.
3. Push in decompression valve.
4. Open the water valve 1/4 turn.
5. Place the saw on stable ground making sure the chain
is free of any obstructions.
6. Place foot on the base of the rear handle, and place one hand on
front handle.
CAUTION
STARTING AND STOPPING A CONCRETE CHAIN SAW
Never start a concrete chain saw without the bar, chain and side cover
properly assembled. Failure to do so may result in serious injury.
Always move a concrete chain saw at least 10 feet (3 m) away from the
fueling area before starting.
Place the saw on clear ground. Ensure that secure footing is
established and chain is not contacting any objects.
IMPORTANT
WARNING
Throttle Trigger
Trigger Interlock
Decompression Valve
Stop Switch
Primer Bulb
Choke
Lever
OPERATION