EasyManuals Logo

ID Tech MINIMAG User Manual

ID Tech MINIMAG
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
6
b3=2 for 10 ms intercharacter delay
b3=3 for 20 ms intercharacter delay
b3=4 for 25 ms intercharacter delay
b3=5 for 50 ms intercharacter delay
EXAMPLE
To set the terminal type to PC-AT, the beep to high, and the interchar
-
acter delay to 5 milliseconds, enter:
/e/d/fa<space>021<ENTER>
Note: Two beeps will be heard if entered numbers are outside the al
-
lowable range.
Change To Default Settings
This command, /e/d/fn, returns all settings for all groups to their de-
fault values. Data Editing will be turned off, and the formulas will be
retained.
Syntax: /e/d/fn<ENTER>
Review Settings
This command, /e/d/fo, activates the review settings command. This
will send the resident settings for the general group to the host com-
puter, allowing you to review them. The firmware version number is
also shown.
Syntax: /e/d/fo<ENTER>

Other manuals for ID Tech MINIMAG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ID Tech MINIMAG and is the answer not in the manual?

ID Tech MINIMAG Specifications

General IconGeneral
InterfaceTTL
Scan speed (max)76.2 mm/sec
Operating voltage5 V
Power consumption4 mA
LED indicatorsYes
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 55 °C
Cable length1.8 m
Weight and Dimensions IconWeight and Dimensions
Weight130 g
Dimensions (WxDxH)34 x 90 x 28 mm