6
b3=2 for 10 ms intercharacter delay
b3=3 for 20 ms intercharacter delay
b3=4 for 25 ms intercharacter delay
b3=5 for 50 ms intercharacter delay
EXAMPLE
To set the terminal type to PC-AT, the beep to high, and the interchar
-
acter delay to 5 milliseconds, enter:
/e/d/fa<space>021<ENTER>
Note: Two beeps will be heard if entered numbers are outside the al
-
lowable range.
Change To Default Settings
This command, /e/d/fn, returns all settings for all groups to their de-
fault values. Data Editing will be turned off, and the formulas will be
retained.
Syntax: /e/d/fn<ENTER>
Review Settings
This command, /e/d/fo, activates the review settings command. This
will send the resident settings for the general group to the host com-
puter, allowing you to review them. The firmware version number is
also shown.
Syntax: /e/d/fo<ENTER>