10
Example: To set the Track Separator to TAB, enter /e/d/fq<space>\
tab<ENTER> (13 keystrokes).
Start/End Sentinel and Track 2 Account Number Only
The MiniMag can be set to either send or not send, to invoke the Start/
End sentinel, and to send either the Track 2 account number only, or
all the encoded data on Track 2. (The Track 2 account number setting
doesn’t affect the output of Track 1 and Track 3.)
Syntax: /e/d/fv<space>b1<ENTER> where...
b1=0 Do not send start/end sentinel, but send all data on all tracks
b1=1 Send start/end sentinel and send all data on all tracks
b1=2 Do not send start/end sentinel, for any track, but send
account number on track 2 only
b1=3 Send start/end sentinel on tracks 1 and 3, and send account
number on track 2 only