INSTALLATION
ESPRIT 2 - Installation and Servicing
21
FITTING THE WALL MOUNTING PLATE (Rear Flue outlet shown)
TO FIT THE WALL MOUNTING PLATE DIRECTLY TO THE WALL
Insert wall plugs.
Put the screws into the wall plugs and leave 10mm proud
Hang the plate onto the screws (take care to use the same
hole position from each group as previously chosen with
the wall template) and tighten up.
Locate the support bracket on the mounting plate.
TO FIT THE WALL MOUNTING PLATE USING THE STAND-OFF
FRAME OPTION KIT
(To allow pipework to be taken upwards)
Put the screws into the wall plugs and leave 10mm proud.
Hang the stand-off frame onto the screws and tighten up.
Fasten the wall mounting plate to the stand-off frame with
the 6mm screws provided.
Locate the support bracket on the mounting plate.
Note.
If the clearances above and below the boiler are less than
the length of the pipes it will be necessary to position the
pipes behind the wall mounting plate BEFORE the plate is
screwed to the wall.
Piping
frame
Wall
plug
Screw
(10mm proud)
Support
bracket
ispfu9798