11 THERMOSTATIC CARTRIDGE REPLACEMENT
This thermostatic cartridge is protected from
water borne debris by mesh lter screens.
These should be checked and cleaned before
contemplating replacing the cartridge.
To replace the thermostatic cartridge:
(REMEMBER TO TURN OFF WATER
SUPPLIES)
1. Prise out the index button.
2. Remove handle screw.
3. Pull off the temperature control handle.
4. To remove the temperature handle carrier (grey
plastic moulding), slide the black serrated lever
clockwise and pull off. This will expose the
thermostatic cartridge.
5. Unscrew cartridge with 24mm A/F spanner and
replace if necessary.
ENSURE PARTS ARE REASSEMBLED IN THE CORRECT
SEQUENCE.
To clean the screens remove the o-rings shown
The screens will then slide off. When clean replace the screens then the
o-rings which should be lightly greased with a WRAS approved silicone
grease (e.g. Klueber Unisilikon GBU2).
lter screens
o-rings
lubricate
before
retting
A 4740 AA, A4741 AA & A 6385 AA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ideal-Standard ALTO ECOTHERM A4741AA and is the answer not in the manual?

Ideal-Standard ALTO ECOTHERM A4741AA Specifications

General IconGeneral
BrandIdeal-Standard
ModelALTO ECOTHERM A4741AA
CategoryMixer
LanguageEnglish

Related product manuals